Arma 3
Оцінок: 113
ADV ACE-CPR (Pike Edition)
2
4
4
2
   
Нагородити
До улюбленого
В улюблених
Прибрати
Data Type: Mod
Розмір файлу
Додано
Оновлено
358.966 KB
2 січ. 2020 о 15:57
23 берез. 2021 о 2:30
Змін 31 ( перегляд )

Підпишіться, аби завантажити
ADV ACE-CPR (Pike Edition)

Опис
This is an updated version of ADV ACE-CPR, made compatible with the ACE medical rewrite (v1.13.X). The functionality of certain aspects of this mod have changed slightly from pre-medical rewrite editions, as detailed below.

Source code: https://github.com/pike713/ADV_Medical/tree/master/adv_aceCPR

Overview:
Giving you a second chance if your everyday CPR doesn't do squat. With ADV - ACE CPR you can finally use ACE CPR to get someone out of the revive state without healing him completely, making gameplay much more interesting. Of course ACE and CBA are required.

After successfully "stabilizing" the patient, he/she will have a basic pulse of at least 30bpm. Doctors have a default 40% success rate and medics have a default 15% success rate. Regular riflemen can resuscitate a patient, but they will have a much lower success rate. They can still keep the patient from dying due to an expired revive timer though.

The success rate is lowered if the patient looses blood or has morphine in his blood system and is raised if the patient received epinephrine right before CPR. The minimum rate is always 2%, unless the player starts with a success probability of 0 (see below).

Depending on your settings (adv_aceCPR_maxTime, see below) you might be too late to resuscitate a player solely with CPR. In that case, the mod provides a new item: a defibrillator. The defibrillator works almost like the CPR action, but you have to have an AED in your inventory and it's much faster and the success rate is way higher. Using the defibrillator will induce pain to all units who stand too close to a patient when the defibrillator is used (except for the operator). By default, you can only use the defibrillator if you're a medic.

The mod also includes the option to use stationary AEDs. You can set the stationary AED objects via CBA settings. Default is Land_Defibrillator_F. You can place a stationary AED via editor or curator. Players can approach the item and use an ACE action to activate the stationary AED. By activating it they have 12 seconds to use it on any unconscious patient in a radius of five meters. After 12 seconds the stationary AED will deactivate again.

Differences from original:
  • In the original mod, the patient would gain a heart rate of 40bpm from the defibrillator. In this version, the patient's heart rate will jump to 120-140bpm instead.
  • The check pulse action override provided by this mod is not active. This may change in the future.
  • The adv_aceCPR_onlyDoctors setting can now restrict AED usage to any ace medic class. This can be adjusted in the CBA settings. Title and description for this setting lack translations.
Популярні обговорення Переглянути всі (1)
0
23 лют. 2020 о 13:35
Server with this mod
jus61
Коментарів: 44
[85OC] John Sheppard 22 трав. о 22:06 
Hello i got bug If you have someone on the ground and have to shock them, the pulse will rise suddenly but then immediately drop to 0 again and then loop without Zeus's help, so you won't be able to wake people up. Because that has to do with the new SPO2 values ​​from ACE, which are now variables. and no longer lie firmly at 120/80, but this only affects a longer lying time, e.g. from 2 minutes or more. Afterwards, Zeus has to heal the people, since doing CPR or using the defibrillator is literally pointless. I tested this with CBA version 3.17.1. ace 3.17.1 after they found a bug in version 3.17.0 where it was added and adv-ACE cpr from I get the same addon options settings and wait times the people wake up again. Unfortunately not anymore with this mod. It would be good if it could be repaired
RaDezZ 26 квіт. о 17:42 
@pike713

Can you update your mod, since the ACE 3 mod was recently updated too?
THANK YOU
R.Wallaby 5 квіт. о 11:41 
another ace update ;(
R.Wallaby 10 листоп. 2023 о 14:16 
Anyone know if this is going to be updated for the new ace update?
Wickle 19 жовт. 2023 о 11:53 
This doesn't seem to work anymore with the new ACE update :(
[S.C.] Raptoid 28 черв. 2022 о 14:50 
@Vulcy I've got the same issue. I think setting it to 100% makes it work but I'd rather not.I'm thinking maybe the ACE update did something.
Vulcy 17 черв. 2022 о 19:50 
hello, im having troubles with this mod. my medic's success rate is set to 90%, and even then the CPR almost never wakes the stable patient up.
Kyroh 14 черв. 2022 о 4:47 
Addon 'adv_aceCPR' requires addon 'ace_medical why am I getting this on my server
Gremzy 23 серп. 2021 о 19:52 
@Pike713 I fixed it. Turns out I was missing a ace compat for one of my mods which messed with ace.
Pike713  [автор] 23 серп. 2021 о 19:30 
@Gremzy I'm unable to reproduce the issue. Could you double check that the defib setting isn't being overriden: for example, if it is defined in the mission settings, check that the corresponding server setting is not set to override mission. If everything is in order, please send me your ADV settings (both server and mission) so that I can preform further testing.